" Strips cut lengthwise or crosswise of the plate to have an ultimate tensile strength of not less than 26 and not exceeding 30 tons per square inch of section, with an elongation of 20 per cent in a length of 8 inches. * See " Manual of the Steam-engine, "
Plating and Boiler-making: A Practical Handbook for Workshop Operations ... - Page 51
by Joseph Gregory Horner - 1920 - 374 pages
Full view - About this book

Notes on building construction [by P.G.L. Smith].

Percy Gaillemard L. Smith - 1879 - 548 pages
...cut lengthways or crossways of the plates, to have an ultimate tensile strength of not less th:in 2G and not exceeding 30 tons per square inch of section, with an elongation of 20 per cent in length of ei^'ht inches. 2. Tempering Tests. — Strips cut lengthways of the plates 1J inch wide,...
Full view - About this book

Transactions of the Royal Institution of Naval Architects, Volume 21

Royal Institution of Naval Architects - Naval architecture - 1880 - 338 pages
...adoption in shipbuilding material. APPENDIX. ADMIRALTY TESTS FOR PLATE, ANGLE, BULB, AND BAR STEEL. Strips cut lengthwise or crosswise, to have an ultimate...with an elongation of 20 per cent, in a length of 8 inches. The beam, angle, bulb, and bar steel to stand such forge tests, both hot and cold, as may be...
Full view - About this book

Steel: Its History, Manufacture, Properties, and Uses

James Stephen Jeans - Steel - 1880 - 966 pages
...as follows : — Tensile and Extension Teds. — 1. Strips cut lengthwise or crosswise of the plate to have an ultimate tensile strength of not less than...with an elongation of 20 per cent, in a length of 8 inches. Tempering Tests. — 2. Strips cut lengthwise of the plate, 1^ inch wide, heated uniformly...
Full view - About this book

Marine Engineer and Motorship Builder, Volumes 1-2

Marine engineering - 1880 - 556 pages
...adoption in shipbuilding material. APPENDIX. ADMIRALTY TESTS FOR PLATE, ANGLE, BULB, AND BAR STEEL. Strips cut lengthwise or crosswise, to have an ultimate...square inch of section, with an elongation of 20 per ceni, in a length of 8 inches. The beam, angle, bulb, and bar steel to stand such forge tests, both...
Full view - About this book

Steel: Its History, Manufacture, Properties, and Uses

James Stephen Jeans - Steel - 1880 - 962 pages
...inch. The tensile strength of the steel in the boilers referred to is reported to be from 38 to 40 tons per square inch of section, with an elongation of 20 per cent, on a length of 4 inches. The holes were all drilled in the plates and the rivets were of iron. For...
Full view - About this book

Minutes of Proceedings of the Institution of Civil Engineers, Volume 69

Institution of Civil Engineers (Great Britain) - Civil engineering - 1882 - 582 pages
...advantage. The Admiralty specification for plates and beams requires : — " Strips cut lengthwise to have an ultimate tensile strength of not less than...with an elongation of 20 per cent. in a length of 8 inches. " Strips cut crosswise or lengthwise 1 £ inch wide, heated uniformly to a low cherry-red and...
Full view - About this book

A Treatise on the Metallurgy of Iron: Containing Outlines of the History of ...

Hilary Bauerman - Iron - 1882 - 588 pages
...Strips cut lengthwise or crosswise to have an ultimate tensile strength of not less than 26 or more than 30 tons per square inch of section, with an elongation of 20 per cent, in a length of 8 inches. Beam, angle, bulb, and bar steel to satisfy such forge tests, hot and cold, as may be sufficient...
Full view - About this book

Naval Professional Papers, Issue 11

United States. Bureau of Naval Personnel - Marine engineering - 1883 - 224 pages
...adoption in ship-building material. APPENDIX. ADMIRALTY TESTS FOR PLATE, ANGLE, BULB, AND BAR STEEL. Strips cut lengthwise or crosswise, to have an ultimate...with an elongation of 20 per cent. in a length of 8 inches. ' . The beam, angle, bulb, and bar steel to stand such forge tests, both hot and cold, as may...
Full view - About this book

Van Nostrand's Engineering Magazine, Volume 28

Engineering - 1883 - 568 pages
...with advantage. The Admiralty specification for plates and beams requires : " Strips cut lengthwise to have an ultimate tensile strength of not less than...with an elongation of 20 per cent, in a length of 8 inches. '• Strips cut crosswise or lengthwise 1£ inch wide, heated uniformly to a low cherry-red...
Full view - About this book

Papers and Discussions on Steel for Ship-building

B. Martell, United States. Bureau of Naval Personnel - Marine steel - 1883 - 218 pages
...AND BAR STEEL. Strips cut lengthwise or crosswise, to have au ultimate tensile strength of not lese than 26 and not exceeding 30 tons per square inch...with an elongation of 20 per cent. in a length of 8 inches. The beam, angle, bulb, and bar steel to stand such forge tests, both hot and cold, as may be...
Full view - About this book